MRS-1100A
PRODUCT DESCRIPTION
The MRS-1100A Modular Rework System is an integrated convection rework system for the removal and reflow of BGA/CSP and SMT components. The MRS-1100A is comprised of a hand held convection tool; preheater, adjustable tool holder, and free-standing board holder to create a manually assisted rework system. A series of nozzles, targeting a variety of applications, and optional light magnifier round out the product offering for this system. With standard features such as programmability, a digital display, program storage of up to 50 profiles, this system is not only versatile, but also easy and efficient to work with.
FEATURES & BENEFITS
-
Digital display for repeatable temperature settings and profile control
-
Automatic control of the preheater for simple operation
-
Easy profile creation for operator repeatability
-
Integrated vacuum pickup for easy component removal
-
Hand held or tool holder mounted for operator comfort
-
Manual mode for quick setup
-
External thermocouple for process setup and verification
-
Digital controlled airflow for repeatable results
-
X, Y, Z and Theta controls for component alignment
-
Adjustable PCB holder for easy change outs
-
Automatic vacuum lift off at the end of the cycle
-
Password lockout of programmed profiles
Product Comprises:
-
HCT-1000 Programmable Hand Held Convection Tool
-
PCT-1000 Programmable Pre-heater
-
ATH-1100A Adjustable Tool Holder
-
BH-2000 Board Holder
TECHNICAL SPECIFICATIONS
HCT-1000
Power:Rated Power 600 Watt
Input Voltage 100-240 VAC, 50/60 Hz
Storage Temperature 0° C to 50° C (32° F to 122° F)
Temperature Range Up to 450° C (840° F)
Air Flow 5-25 I/minute
Vacuum Pump 15″ Hg (381mm Hg)
Noise level <55 dB
Approvals TUV
PCT-1000
Rated Power 1200 Watt
Input 100-240 VAC, 50/60 Hz
Storage Temperature 0° C to 50° C (32° F to 122° F)
Temperature Range 25° C to 350° C (77° F to 660° F)
Temperature Control Type K thermocouple feedback with user selectable source (internal) or target (external) control.
External includes two Type K inputs
Air Flow Fixed at 19cfm (538 I/minute)
Operational modes Setup, Run, Manual, Active Setup
Display LCD 20 x 4 display segments
Number of programs 50 memory locations
Number of Zones 5 (4 Heat zones, 1 Cool down zone)
Approvals CE, cTUVus